It appears that your cart is currently empty
Code | Description | Check, repair/replace as necessary |
A5 | Tank NTC defect | check tank NTC and leads |
A7 | DHW NTC defect | check hot water NTC and connecting lead |
A8 | EMS coms error | check electrical connections. |
b1 | Code plug not detected | Insert code plug correctly. |
b2,b3,b4, b5,b6 |
Data error | software/pcb error |
b7 | Burner control error | software/pcb error |
C6 | Fan defect | check fan, lead and connector. |
D3 | External Temp limiter | check external stat. |
D5 | Condensate overflow | check condensate pump and leads. |
D6 | Internal heatbank overheated | check tank overheat thermostat |
EA | Burner control lockout | check gas supply and igniter electrode. |
E2 | Primary NTC defect | check CH NTC and lead. |
E9 | OH stat tripped | check system pressure and pump. |
F0 | Internal error | check electrical connector contacts. |
F1 | Rom check error | software/pcb error. |
F7 | Flame detected after appliance shut off | check electrode assembly, dry pcb. |
FA | Flame detected after gas shut off | check gas valve and leads |
Fd | Reset button pressed | press reset button again. |