Worcester Greenstar HE plus combi ZWBR7-30 Boiler Fault Codes

 Code Description Remedy
A1 Pump has run dry Check system pressure, add water and bleed system as necessary
A7 Hot water NTC sensor defective Check hot water NTC sensor and connecting lead for circuit breaks/short circuits
A8 Break in communication Check connecting lead to TR2
b1 Keyed plug not detected. Insert keyed plug correctly, test and replace if necessary.
C1 Fan speed too low. Check fan lead and connector, and fan; replace as necessary.
d3 Jumper 8-9 not detected. Connector not connected, link missing, underfloor heating limiter tripped.
E2 CH flow NTC sensor defective Check CH flow NTC sensor and connecting lead.
E9 Safety temp. limiter in CH flow has tripped. Check system pressure, check safety temp. limiters, check pump operation, check fuse on pcb, bleed appliance.
EA Flame not detected. Is gas cock turned on? Check gas supply pressure, power supply, igniter electrode and lead, ionisation sensing electrode and lead, flue duct and CO2 level.
F0 Internal error. Check electrical connector contacts, programmer interface module ignition leads are not loose; replace pcb if necessary.
F7 Flame detected even though appliance switched off. Check electrode assembly, dry pcb. Flue clear?
FA Flame detected after gas shut off. Check gas valve and wiring to gas valve. Clean condensation trap and check electrode assembly. Flue clear?
FC Text display not detected Check connecting lead between textdisplay & Heatronic, replace textdisplay if necessary
Fd Reset button pressed by mistake. Press reset button again

P1,P2,P3,

P1...

Please wait, initialisation in progress. 24 V fuse blown. Replace fuse.