Worcester Greenstar FS42 CDi Regular LPG Boiler Fault Codes

 Code Description Check, repair/replace as necessary
A8 EMS coms error check electrical connections
b1 Code plug not detected Insert code plug correctly

b2,b3,b4,

b5,b6

Data error software/PCB error
b7 Burner control error software/PCB error
C6 Fan defect check fan, lead and connector
D5 Condensate overflow check condensate pump and leads.
EA Burner control lockout check gas supply and igniter electrode
E2 Primary NTC defect check NTC and lead.
E9 OH stat tripped Check system pressure and pump
F0 Internal error check electrical connector contacts.
F1 ROM check error software/PCB error.
F7 Flame detected after appliance shut off check electrode assembly, dry PCB
FA Flame detected after gas shut off check gas valve and leads.
Fd Reset button pressed press reset button again.