Worcester Greenstar 30 Ri Compact LPG ErP Boiler Fault Codes

 
Flash Sequence Type of Fault Fault Possible Solutions
Light OFF No fault No boiler demand - boiler is OK
Light ON Heating demand on boiler- boiler is OK
Group 1 Flashing codes
1 Locking No ionisation detection after ignition Failure of four ignition attempts, the boiler waits 30 seconds before another attempt is made. Reset the boiler by turning the control knob anticlockwise to the reset position.
2 Locking Loss of ionisation signal during operation An established flame has been extinguished. Reset the boiler by turning the control knob anticlockwise to the reset position.
3 Locking Gas valve error Gas valve coil disconnected. Check gas valve. Reset the boiler by turning the control knob anticlockwise to the reset position.
4 Locking First safety timing error/ignition timing error The flame was not established during the first four seconds of the ignition period. Reset the boiler by turning the control knob anticlockwise to the reset position.
5 Locking

Ionisation detected after burner stopped

Gas valve EV2 leak test failed

Gas valve EV1 leak test failed

Ionisation current detected before burner-start

Gas valve error

Ionisation sensor shorted

Gas valve leaking.

False flame detected.

Reset the boiler by turning the control knob anticlockwise to the reset position.

 Flash Sequence Type of Fault Fault Possible Solution
Light OFF No boiler demand - boiler is OK
Light ON Heating demand on boiler- boiler is OK
Group 2 Flashing codes
6 Locking Sensor test failed On power up all safety sensors are checked, the check failed. Reset the boiler by turning the control knob anticlockwise to the reset position.
7 Locking Safety temperature too high The main heat exchanger has overheated. Maximum temperature 105°C. Reset the boiler by turning the control knob anticlockwise to the reset position.
8 Blocking MAX safety thermostat activated Flue gas thermostat overheat or APS activated
9 Locking Return temperature too high Boiler overheat. Reset the boiler by turning the control knob anticlockwise to the reset position.
10 Locking

Flow temperature too high -

Supply sensor exceeded 110°C

Primary flow sensor overheated. Reset the boiler by turning the control knob anticlockwise to the reset position.
 Flash Sequence Type of Fault Fault Possible Solution
Light OFF No boiler demand - boiler is OK
Light ON Heating demand on boiler- boiler is OK
Group 3 Flashing codes
11 Locking HCM (Heat Control Module) Defective Incorrect, faulty, or missing HCM. Replace HCM with correct item Reset the boiler by turning the control knob anticlockwise to the reset position.
12 Locking

Fan running too fast

Fan running too slow

No airflow after defined period of time

Fan not running

Defective fan or blocked air way. Reset the boiler by turning the control knob anticlockwise to the reset position.
13 Locking Mains voltage interrupted after locking error Reset the boiler by turning the control knob anticlockwise to the reset position.
14 Locking Internal control board faults Call Worcester, Bosch Group technical help-line 0330 123 3366
15 Locking All other faults Miscellaneous Reset the boiler by turning the control knob anticlockwise to the reset position.