Vaillant TurboMAX Plus 837 E Boiler Fault Codes

Vaillant Boilers
 Display Indication Displayed values/adjustment values
F00

Flow-NTC:

NTC broken; NTC cable broken; Defective connection at NTC Defective connection at electronics

Flow-NTC cable defective/ broken NTC faulty
F01

Return NTC:

NTC broken; NTC cable broken; Defective connection at NTC Defective connection at electronics

Return-NTC cable defective/broken NTC faulty
F10 Short circuit - flow-NTC (<130°C) NTC-plug shorted to casing, NTC defective
F11 Short circuit - return-NTC (<130°C) NTC-plug shorted to casing, NTC defective
F20 Over heat cut off activated Maximum temperature exceeded
F22 Dry fire protection No water in appliance, pump cable defective, pump blocked or defective, pump output too low
F23 Dry fire protection (difference between flow and return NTC's too large) No water in appliance, pump cable defective, pump blocked or defective, pump output too low
F24 Dry fire protection (temperature gradient of flow NTC too steep) Air in boiler/system, pump blocked or defective, pump output too low
F27 No demand to gas valve Electronic board defective; Gas valve defective
F28 Boiler goes to lock out No gas; Insufficient gas; Incorrect gas valve adjustment; Electrode defective; Ignition lead defect; Electronic igniter defective
F29 Flame extinguished re-ignition unsuccessful Gas supply absent or insufficient

F32

(837/637 only)

Main heat exchanger anti freeze protection mode  due to fan speed deviation too great Check fan control cables/connections; Defective fan control cable;

F33

(837/637 only)

Main heat exchanger anti freeze protection mode  due to no switching signal from the air pressure switch Check air pressure switch, fan, fan supply or flue system

F37

defect

(837/637 only)

The rotary speed of the fan is too high or too low Air pressure switch defect; fan defect; electronics

F41

(837/637 only)

No setting for the type of gas is stored Set gas type in PCB (see page 30)
F42 Faulty cable loom Faulty or incorrect loom fitted
F43 Faulty cable loom Faulty or incorrect loom fitted
F60 Electronic fault Electronics defect
F61 Electronic fault Electronics defect
F62 Flame rectification present 4 secs. after gas valve turns off Check gas valve, burner tubes and injectors or electronics defect
F63 EMC fault EMC or electronics defect
F64 Sensor or electronics fault Check NTC's/connections or electronics defect
F65 PCB processor temperature too high Check earth connection or electronics defect
F66 Display fault Display defect; fault in the connection to the display; electronics defect
F67 Electronic fault Electronics defect