 Display Indication Displayed values/adjustment values
F00

Flow-NTC:

NTC broken; NTC cable broken; Defective connection at NTC Defective connection at electronics

Flow-NTC cable defective/ broken NTC faulty
F01

Return NTC:

NTC broken; NTC cable broken; Defective connection at NTC Defective connection at electronics

Return-NTC cable defective/broken NTC faulty
F10 Short circuit - flow-NTC (<130°C) NTC-plug shorted to casing, NTC defective
F11 Short circuit - return-NTC (<130°C) NTC-plug shorted to casing, NTC defective
F20 Over heat cut off activated Maximum temperature exceeded
F22 Low water or no water in appliance No water in system Pump defective Pump lead defective
F27 No demand to gas valve Electronic board defective; Gas valve defective
F28 Boiler goes to lock out No gas; Insufficient gas; Incorrect gas valve adjustment; Electrode defective; Ignition lead defect; Electronic igniter defective
F29 Flame extinguished re-ignition unsuccessful Gas supply absent or insufficient
F42 Faulty cable loom Faulty or incorrect loom fitted
F43 Faulty cable loom Faulty or incorrect loom fitted
F60 to F67 Irreversible electronic system malfunction Electronic system defective