Display | Fault |
'01' and 'F' and 'flashing red LED' | Ignition fault (lockout) caused by no gas, no detection |
'02' and 'F' and 'flashing red led' | Air fault, pressure switch, no power to fan |
'05' and 'F' and 'flashing red LED' | Overheat fault |
'06' and 'F' and 'flashing red LED | Central heating flow NTC fault |
'09' and 'F' and 'flashing red LED' | Water pressure sensor fault |
'11' and 'F' and 'flashing red LED' | No reception by the main board (MMI Lead) |
'12' and 'F' and 'flashing red LED' | User interface or distant control panel fault |
'13' and 'F' and 'flashing red LED' | Main board fault |
'14' and 'flashing red LED' | Over temperature on primary water circuit |
'15' and 'F' and 'flashing red LED' | Stepper motor fault (gas valve) |
'16' and 'F' and 'flashing red LED' | Gas safety value failure |
'17' and 'F' and 'flashing red LED' | Power supply <170V |
'18' and 'F' and 'flashing red LED' | Local user interface fault |
'19' and 'F' and 'flashing red LED | Central heating NTC not connected to pipe |
'20' and 'F' and 'flashing red LED' | User interface not compatible with boiler |
'0.5bar' flashing and 'F' and 'flashing red LED' | Lack of water fault (<0.5b) |
'2.7bar' flashing and 'F' and 'flashing red LED' | Upper water pressure (>2.7b) |
Type of Fault | Check |
No display on control panel |
• 230V supply • PCB fuse • Connection between PCBs |
No domestic hot water 24ci Only) No central heating (Red flashing warning light and flashing disconnected, fault code in display) |
• Loose connections on control board (PCB) • Connections on air pressure switch (electrical or tubes) • Faulty control or interface board (PCB's) • Water pressure, flashing pressure • Shortage of air or gas • Faulty temperature sensor • Overheating, |