Glowworm 18 SI Boiler Fault Codes

Glowworm boilers

 Display Fault
'01' and 'F' and 'flashing red LED' Ignition fault (lockout) caused by no gas, no detection
'02' and 'F' and 'flashing red led' Air fault, pressure switch, no power to fan
'05' and 'F' and 'flashing red LED' Overheat fault
'06' and 'F' and 'flashing red LED Central heating flow NTC fault
'09' and 'F' and 'flashing red LED' Water pressure sensor fault
'11' and 'F' and 'flashing red LED' No reception by the main board (MMI Lead)
'12' and 'F' and 'flashing red LED' User interface or distant control panel fault
'13' and 'F' and 'flashing red LED' Main board fault
'14' and 'flashing red LED' Over temperature on primary water circuit
'15' and 'F' and 'flashing red LED' Stepper motor fault (gas valve)
'16' and 'F' and 'flashing red LED' Gas safety value failure
'17' and 'F' and 'flashing red LED' Power supply <170V
'18' and 'F' and 'flashing red LED' Local user interface fault
'19' and 'F' and 'flashing red LED Central heating NTC not connected to pipe
'20' and 'F' and 'flashing red LED' User interface not compatible with boiler
'0.5bar' flashing and 'F' and 'flashing red LED' Lack of water fault (<0.5b)
'2.7bar' flashing and 'F' and 'flashing red LED' Upper water pressure (>2.7b)

 

 Type of Fault Check
No display on control panel

• 230V supply

• PCB fuse

• Connection between PCBs

No domestic hot water 24ci Only)

No central heating

(Red flashing warning light and flashing disconnected, fault code in display)

• Loose connections on control board (PCB)

• Connections on air pressure switch (electrical or tubes) 

• Faulty control or interface board (PCB's)

• Water pressure, flashing pressure • Shortage of air or gas

• Faulty temperature sensor

• Overheating,